 			Posted on 2013-09-11 18:41 eryar  阅读(7647) 评论(28)  编辑 收藏 引用   所属分类: 4.AVEVA Solution  、3.PlantAssistant   配置方法见程序文档说明或:http://www.cppblog.com/eryar/archive/2013/05/01/199875.html 
   RvmTranslator2.1  [20150818]
 ----------------
 1. Improve performance for STEP translation;
 2. Finish parse all the primitive shapes in RVM file;
 
 
 RvmTranslator2.0  [20150504]
 ----------------
 1. Thanks to SudoSky, RvmTranslator can parse binary RVM files.
 
 
 RvmTranslator1.0  [20150422]
 ----------------
 RvmTranslator - Translate PDMS RVM to STEP, IGES, STL, etc.
 1. Standalone program to export PDMS model to STEP, IGES, STL .etc. by RVM file.
 2. The RvmTranslator only rely on RVM file, it has no relation with PDMS SP12.0 or SP12.1.
 3. The RvmTranslator only can parse ASCII text RVM files.
   
 RvmTranslator Usage: Download: 
 2014-07-13==========
 ModelDataExchangeAddin V1.2
 1. Update the ModelDataExchangeAddin to AVEVA 12.1; Download:     
 2014-03-20
 ==========
 ModelDataExchangeAddin V1.1
 1. Skip null Catref of Nozzles;2. Skip some zero primitives shapes;
     2013.09.11========
 1. 可以导出设备模型(Export equipment model);
 2. 可以导出管路模型(Export pipe model);
  
 Figure 1.1 Pipe and equipment models in PDMS    
 Figure 1.2 Pipe and equpment models exported by ModelDataExchange in Google SketchUp 
	    
    
Feedback
				
					
						# re: AVEVA Model Data Exchange ChangeLog  回复  更多评论
						  
					
					2013-09-16 18:43 by 
				 I am very interested to see this magic.... 
				
					
						# re: AVEVA Model Data Exchange ChangeLog  回复  更多评论
						  
					
					2013-09-16 18:49 by 
				 I am very interested to see this magic .... 
				
					
						# re: AVEVA Model Data Exchange ChangeLog  回复  更多评论
						  
					
					2013-09-16 20:34 by 
				 Hi, Rafique Gazalli:You can download this .Net Addin to have a try, enjoy!
 :-)
 @Rafique Gazalli
 
 
				
					
						# re: AVEVA Model Data Exchange ChangeLog  回复  更多评论
						  
					
					2013-09-22 21:48 by 
				 能完整导入CAD么?包括壁厚信息等 
				
					
						# re: AVEVA Model Data Exchange ChangeLog  回复  更多评论
						  
					
					2013-09-22 22:01 by 
				 只要壁厚定义了,就可以,但是如果只看看管子模型,壁厚导出并显示出来的意义不大。现在是全部导出,没有考虑Representation level,保温效果什么的都可以导出
 @shan
 
 
				
					
						# re: AVEVA Model Data Exchange ChangeLog  回复  更多评论
						  
					
					2013-09-24 15:40 by 
				 你有qq或者其他联系方式么?想私聊,我的qq 119828528
谢谢
 
				
					
						# re: AVEVA Model Data Exchange ChangeLog  回复  更多评论
						  
					
					2013-09-24 22:35 by 
				 一般邮箱:eryar(at)163.comQQ已加,
 @shan
 
 
				
					
						# re: AVEVA Model Data Exchange ChangeLog  回复  更多评论
						  
					
					2013-10-08 14:22 by 
				 2013.09.11
========
 1. 可以导出设备模型(Export equipment model);
 2. 可以导出管路模型(Export pipe model);
 
 这个版本在哪里能下载到?想尝试一下
 
				
					
						# re: AVEVA Model Data Exchange ChangeLog  回复  更多评论
						  
					
					2013-10-11 23:44 by 
				 现在还没有编译一个Release版本的出来,若想试用,请email联系。有时间发布一个Release试用版本。
 @sopot
 
 
				
					
						# re: AVEVA Model Data Exchange ChangeLog[未登录]  回复  更多评论
						  
					
					2014-10-21 12:26 by 
				 v1.1在PDMS Sample项目的/STABILIZER模型中导出/Pipes报错:Element SCOMPONENT /CAVABDRRR does not have attribute DESPAveva.Pdms.Utilities.Messaging.Implementation.PdmsExceptionImpl: 应用程序中的错误。
 
 另外导出的StL模型面太多,很难实用。
 
				
					
						# re: AVEVA Model Data Exchange ChangeLog  回复  更多评论
						  
					
					2014-10-21 17:35 by 
				 @WangHi Wang,
 
 你好!
 
 感谢你的反馈,Sample也是我的测试工程,其中这个SITE的PIPE大部分都已经通过测试。我再试试看你的这个模型。
 
 导出的STL面多,模型显示更细腻、精确,可以考虑加个精度设置。
 
				
					
						# re: AVEVA Model Data Exchange ChangeLog[未登录]  回复  更多评论
						  
					
					2015-03-05 11:09 by 
				 您好!我用的是12.1sp2,导出的时候,程序无响应,然后退出了,尝试了很多次,是什么原因呢? 
				
					
						# re: AVEVA Model Data Exchange ChangeLog  回复  更多评论
						  
					
					2015-03-05 19:19 by 
				 @leo
 Hi leo,
 
 你是用的哪个版本?是ModelDataExchangeAddin V1.2这个版本不?
 12.1需要用这个版本的。
 
 Best Regards,
 Shing Liu
 
				
					
						# re: AVEVA Model Data Exchange ChangeLog[未登录]  回复  更多评论
						  
					
					2015-03-11 15:04 by 
				 @eryarHi eryar,
 
 我用的是V1.2的,cmd窗口有这样的提示,看不懂了,需要您的帮助:
 
 AVEVA PDMS Design Mk12.1.SP2.0[3043]
 
 ***WARNING*** No schematic database present - Schematic 3D Integrator not initial
 ised
 Warning: Failed to load addin assembly E:\AVEVA\Plant\PDMS12.1.SP2\ModelChangesAd
 din.dll
 Addin assembly E:\AVEVA\Plant\PDMS12.1.SP2\ModelChangesAddin.dll could not be fou
 nd
 Unhandled Exception:
 
 ????????????????
 
 System.Reflection.TargetInvocationException
 
 Stack Trace:
 ?? System.RuntimeMethodHandle._InvokeMethodFast(Object target, Object[] argume
 nts, SignatureStruct& sig, MethodAttributes methodAttributes, RuntimeTypeHandle t
 ypeOwner)
 ?? System.RuntimeMethodHandle.InvokeMethodFast(Object target, Object[] argumen
 ts, Signature sig, MethodAttributes methodAttributes, RuntimeTypeHandle typeOwner
 )
 ?? System.Reflection.RuntimeMethodInfo.Invoke(Object obj, BindingFlags invokeA
 ttr, Binder binder, Object[] parameters, CultureInfo culture, Boolean skipVisibil
 ityChecks)
 ?? System.Reflection.RuntimeMethodInfo.Invoke(Object obj, BindingFlags invokeA
 ttr, Binder binder, Object[] parameters, CultureInfo culture)
 ?? Aveva.ApplicationFramework.Presentation.Command.Execute(ArrayList arguments
 )
 ?? Aveva.ApplicationFramework.Presentation.Command.CancelableExecute(ArrayList
 arguments)
 ?? Aveva.ApplicationFramework.Presentation.ButtonToolImpl.FireToolClick()
 ?? Aveva.ApplicationFramework.Presentation.CommandBarManagerImpl._toolbarManag
 er_ToolClick(Object sender, ToolClickEventArgs e)
 ?? Infragistics.Win.UltraWinToolbars.UltraToolbarsManager.OnToolClick(ToolClic
 kEventArgs e)
 ?? Infragistics.Win.UltraWinToolbars.UltraToolbarsManager.FireEvent(ToolbarEve
 ntIds id, EventArgs e)
 ?? Infragistics.Win.UltraWinToolbars.ToolBase.OnToolClick()
 ?? Infragistics.Win.UltraWinToolbars.ButtonToolUIElement.DoClickProcessing(Mou
 seEventArgs e)
 ?? Infragistics.Win.UltraWinToolbars.ButtonToolUIElement.OnMouseUp(MouseEventA
 rgs e)
 ?? Infragistics.Win.ControlUIElementBase.ProcessMouseUpHelper(Object sender, M
 ouseEventArgs e)
 ?? Infragistics.Win.ControlUIElementBase.ProcessMouseUp(Object sender, MouseEv
 entArgs e)
 ?? Infragistics.Win.Utilities.ProcessEvent(Control control, ProcessEvent event
 ToProcess, EventArgs e)
 ?? Infragistics.Win.UltraControlBase.OnMouseUp(MouseEventArgs e)
 ?? Infragistics.Win.UltraWinToolbars.UltraToolbarsDockArea.OnMouseUp(MouseEven
 tArgs e)
 ?? System.Windows.Forms.Control.WmMouseUp(Message& m, MouseButtons button, Int
 32 clicks)
 ?? System.Windows.Forms.Control.WndProc(Message& m)
 ?? System.Windows.Forms.Control.ControlNativeWindow.OnMessage(Message& m)
 ?? System.Windows.Forms.Control.ControlNativeWindow.WndProc(Message& m)
 ?? System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr w
 param, IntPtr lparam)
 E:\AVEVA\Plant\PDMS12.1.SP2\des.exe : A fatal error has been detected.
 The program must exit.
 
				
					
						# re: AVEVA Model Data Exchange ChangeLog  回复  更多评论
						  
					
					2015-03-11 19:29 by 
				 @leoHi leo,
 
 你用过ModelDataExchangeAddin V1.1么?配置成功过不?
 
 
 
				
					
						# re: AVEVA Model Data Exchange ChangeLog  回复  更多评论
						  
					
					2015-03-11 19:29 by 
				 @leo
 AVEVA PDMS Design Mk12.1.SP2.0[3043]
 
 ***WARNING*** No schematic database present - Schematic 3D Integrator not initial
 ised
 Warning: Failed to load addin assembly E:\AVEVA\Plant\PDMS12.1.SP2\ModelChangesAd
 din.dll
 Addin assembly E:\AVEVA\Plant\PDMS12.1.SP2\ModelChangesAddin.dll could not be fou
 nd
 Unhandled Exception:
 
 ????????????????
 看上面的报错,应该是没有正确配置所致。
 
				
					
						# re: AVEVA Model Data Exchange ChangeLog  回复  更多评论
						  
					
					2015-04-03 10:17 by 
				 hi eryar. This is free or commercial software? 
				
					
						# re: AVEVA Model Data Exchange ChangeLog  回复  更多评论
						  
					
					2015-04-06 19:29 by 
				 @pdms
Hi pdms,
 
 you can download the Addin to check its license.
 The Addin is free.
 
 Best Regards,
 Shing Liu
 
				
					
						# re: AVEVA Model Data Exchange ChangeLog  回复  更多评论
						  
					
					2015-04-10 17:45 by 
				 Hi Eryar ,
 Thank you for uploading such a good addin.
 
 I am the usee of PDMS version 12.0SP6 and 12.SP4.
 
 I can able to export the model  form the 12.0SP6 with the help of Addin version 1.1 .
 
 But when i load the addin v1.2 for PDMS 12.1SP4.
 
 I could not able to do and i can see the following error in the PDMS console.
 
 
 PLEASE give your valuable replay to this such that i can start using this in PDMS 12.1SP4.
 
 In addition is there any chance to export complete Site or Zone from the PDMS.
 
 
 eRROR,
 
 System.Reflection.TargetInvocationException Stack Trace: ?? System.RuntimeMethodHandle._InvokeMethodFast (Object target, Object [] argume nts, SignatureStruct & SIG, MethodAttributes MethodAttributes, RuntimeTypeHandle t ypeOwner) ?? System.RuntimeMethodHandle.InvokeMethodFast (Object target, Object [] argumen TS, Signature SIG, MethodAttributes MethodAttributes, RuntimeTypeHandle typeOwner ) ?? System.Reflection.RuntimeMethodInfo.Invoke (Object obj, BindingFlags invokeA ttr, Binder Binder, Object [] parameters, CultureInfo Culture, Boolean skipVisibil ityChecks) ?? System.Reflection.RuntimeMethodInfo.Invoke (Object obj, BindingFlags invokeA ttr, Binder Binder, Object [] parameters, CultureInfo Culture) ? ? Aveva.ApplicationFramework.Presentation.Command.Execute (ArrayList arguments ) ?? Aveva.ApplicationFramework.Presentation.Command.CancelableExecute (ArrayList arguments) ?? Aveva.ApplicationFramework.Presentation.ButtonToolImpl.FireToolClick () ?? Aveva.ApplicationFramework.Presentation. CommandBarManagerImpl._toolbarManag er_ToolClick (Object Sender, ToolClickEventArgs e) ?? Infragistics.Win.UltraWinToolbars.UltraToolbarsManager.OnToolClick (ToolClic kEventArgs e) ?? Infragistics.Win.UltraWinToolbars.UltraToolbarsManager.FireEvent (ToolbarEve ntIds ID, EventArgs e) ?? Infragistics. Win.UltraWinToolbars.ToolBase.OnToolClick () ?? Infragistics.Win.UltraWinToolbars.ButtonToolUIElement.DoClickProcessing (Mou seEventArgs e) ?? Infragistics.Win.UltraWinToolbars.ButtonToolUIElement.OnMouseUp (MouseEventA RGS e) ?? Infragistics.Win.ControlUIElementBase.ProcessMouseUpHelper (Object Sender, M ouseEventArgs e) ?? Infragistics.Win.ControlUIElementBase.ProcessMouseUp (Object Sender, MouseEv entArgs e) ?? Infragistics.Win.Utilities.ProcessEvent (Control Control, ProcessEvent Event ToProcess, EventArgs e) ?? Infragistics.Win .UltraControlBase.OnMouseUp (MouseEventArgs e) ?? Infragistics.Win.UltraWinToolbars.UltraToolbarsDockArea.OnMouseUp (MouseEven tArgs e) ?? System.Windows.Forms.Control.WmMouseUp (Message & m, MouseButtons button, Int 32 Clicks) ?? System. Windows.Forms.Control.WndProc (Message & m) ?? System.Windows.Forms.Control.ControlNativeWindow.OnMessage (Message & m) ?? System.Windows.Forms.Control.ControlNativeWindow.WndProc (Message & m) ?? System.Windows .Forms.NativeWindow.Callback (IntPtr hWnd, Int32 msg, IntPtr w param, IntPtr lparam) E: \ AVEVA \ Plant \ PDMS12.1.SP2 \ des.exe:. A fatal Error detected HAS Been MUST Exit The Program.
 
				
					
						# re: AVEVA Model Data Exchange ChangeLog  回复  更多评论
						  
					
					2015-04-10 21:16 by 
				 @MOhamed Auswath Khan
 Hi Mohanmed,
 
 Thanks for your feedback. I am very happy that the addin can do something useful.
 
 The Addin can export the SITE or ZONE if you select it, but the
 export process maybe a little slowly.
 
 I will check the addin v1.2 for PDMS 12.1SP4.
 
 Best Regards,
 Shing Liu
 
				
					
						# re: AVEVA Model Data Exchange ChangeLog  回复  更多评论
						  
					
					2015-04-13 13:12 by 
				 Hi Shing Liu,
 Thank you for the quick replay ,
 
 I am eager to use this in PDMS 12.1SP4 as most of our projects are running in this version.
 
 I will be eagerly waiting for your post.
 
 
 Thank You,
 
 With regards,
 Mohamed Auswath khan.Z
 
 
				
					
						# re: AVEVA Model Data Exchange ChangeLog  回复  更多评论
						  
					
					2015-04-13 19:23 by 
				 @MOhamed Auswath Khan
 Hi Mohanmed,
 
 You are welcome.
 
 Thanks for your attention, I will update the ModelDataExchangeAddin to 12.1 soon...
 
 Best Regards,
 Shing Liu
 
				
					
						# re: AVEVA Model Data Exchange ChangeLog  回复  更多评论
						  
					
					2015-04-15 21:25 by 
				 Hi Shing Liu,
 
 Will be waiting for you replay
 
 With regards,
 Mohamed Auswath khan.Z
 
				
					
						# re: AVEVA Model Data Exchange ChangeLog  回复  更多评论
						  
					
					2015-04-17 19:42 by 
				 @MOhamed Auswath Khan
 Hi Mohanmed,
 
 I will develop a standalone program to export PDMS model to STEP, IGES, STL .etc. by rvm file. The standalone program will have no relation with PDMS, no matter which version of PDMS you use, only rely on the rvm file exported by PDMS.
 
 Best Regards,
 Shing Liu
 
				
					
						# re: AVEVA Model Data Exchange ChangeLog  回复  更多评论
						  
					
					2015-04-21 21:20 by 
				 Hi Shing Liu,
 You guys are doing excellent job.
 
 Reducing the efforts of other 3rd party software.
 
 I am waiting to test what you have explained in the above post
 
 With regards,
 Mohamed Auswath khan.Z
 
				
					
						# re: AVEVA Model Data Exchange ChangeLog  回复  更多评论
						  
					
					2015-04-21 22:47 by 
				 @MOhamed Auswath Khan
 Hi Mohamed,
 
 Thank you.
 
 I hope the application will be useful.
 
 I will release the first version of RvmTranslator soon,
 then you can download it and have a try...
 
 
 
				
					
						# re: AVEVA Model Data Exchange ChangeLog  回复  更多评论
						  
					
					2015-06-30 19:09 by 
				 hi,i used rvm translator 2 and found it is working and can read the files.
 I have a doubt can exported item is treated as a single entity. Can we make it as multiple entities like pipe, flange, elbow, etc when we select
 
				
					
						# re: AVEVA Model Data Exchange ChangeLog  回复  更多评论
						  
					
					2015-06-30 19:28 by 
				 @gopi
 Hi gopi,
 
 Thanks for your feedback.
 
 RvmTranslator is used to translate the geometry model in RVM files, because the export result are STEP, IGES, STL, .etc format, such as STL only contains model mesh, do not contains assembly info, so if you want to export as a multiple entities, will be result many files per entity.
 
 Best Regards,
 Shing Liu
 |